Wednesday, September 21, 2011

Object is read only because it was created by a future version of Exchange: 0.10 (14.0.100.0). Current supported version is 0.1 (8.0.535.0).

Issue: Removing Exchange PF database fails with fallowing error on E07 Server

image

  • The public folder database 'SG02PF1' cannot be deleted.
  • SG02PF1
  • Failed
  • Error:
  • Object is read only because it was created by a future version of Exchange: 0.10 (14.0.100.0). Current supported version is 0.1 (8.0.535.0).

Solution:

Log onto Exchange 2010 Server use fallowing PS command

  • Server Name:WINCMS
  • Storage Group Name  SG02
  • Database Name: SG02PF1
Remove-PublicFolderDatabase -Identity "WINCMS\SG02\SG02PF1"

image

Respectfully,
Oz Casey, Dedeal ( MVP north America)
MCITP (EMA), MCITP (SA)
MCSE 2003, M+, S+, MCDST
Security+, Project +, Server +
http://smtp25.blogspot.com/ (Blog)
http://telnet25.wordpress.com/ (Blog)

0 comments: